  • HOW to Know Your Instruments are Clean, and WHY it Matters!
Dental Office Education Dental Products Partner Organizations

HOW to Know Your Instruments are Clean, and WHY it Matters!

OffTheCusp Guest Author OffTheCusp Guest AuthorSeptember 16, 2016September 15, 2017
how to know your instruments are clean

Share

Facebook
Twitter
Pinterest
LinkedIn
Email
Read Time:5 Minute, 3 Second

how to know your instruments are cleanLet’s face it, cleaning and sterilizing instruments for re-use might just be one of the most tedious and dull parts of your day. But the bottom line is that it is also a crucial part of your day. Ensuring that instruments are free of potentially infectious material and debris is critical to the quality care that dental health professionals pledge to provide.

 

The Importance of Clean

The essential first step in instrument reprocessing is successful cleaning, and it’s important to get it right. If an instrument is not properly cleaned and any kind of bioburden or foreign material is left on its surface, it can act as a barrier to the sterilizing agent (usually steam). In effect, if an instrument is not properly cleaned, it cannot be sterile.

All organic and inorganic residue must be removed in order to achieve sterility. Organic material like blood and plaque could lead to a health care associated infection if left on an instrument. Inorganic material such as cements and composites could lead to an instrument rusting or pitting, rendering it un-useable and reducing its useful life.

Instrument Surface Chart

 

Common Process Failures

These days, the majority of instrument cleaning is achieved via an automated process such as ultrasonic cleaners or washer-disinfectors. With ultrasonic cleaners, instruments are fully submerged in a detergent solution while bubbles (cavitation) continuously form and burst, removing soil by breaking the bonds that hold debris on instruments. Washer-disinfectors use water and detergent at high temperatures to force debris from instruments both directly via pressure, as well as indirectly through soaking in the water and detergent mixture.

In both automated cleaning processes there are a number of parameters at play that combine to produce an effective cleaning process:

Washer-Disinfectors Ultrasonic Cleaners
Time Cavitation
Temperature Time
Concentration of detergent Temperature
Spray arm function Amount of detergent
Enzyme/detergent soak Number of instruments

All of these factors work together in order to effectively clean instruments. If one of these parameters fails or is inconsistent, your cleaning process could be in jeopardy! Any number of things could potentially go wrong with each parameter. Below are some examples of things that could cause one of these parameters to fail or be insufficient:

Washer-Disinfectors Ultrasonic Cleaners
Inadequate water spray/impingement Ineffective cavitation
Clogged spray arms Overloading
Overloading and instrument shadowing Insufficient time, temperature, and/or detergent
Inadequate/improper detergent dosage

 

Monitoring the Cleaning Process

The mechanics of sterilization monitoring are fairly well known – a chemical indicator in each pack and regular biological monitor testing of each sterilizer. These are performed on a routine basis as a check to ensure the sterilization process is functioning properly. But, if an instrument that is not clean cannot be sterilized, isn’t it just as important to monitor the cleaning process to ensure it’s being performed properly?

Sure, you might glance at the instruments after they have been cleaned to see if there is anything left on them, similar to when you empty the dishwasher at home, but not all blood components are always visible to the naked eye. And what about those areas of an instrument that are not visible, like the hinges on scissors and forceps?

bloody pair of dental forcepsA common practice for testing an ultrasonic cleaner is to perform a foil test. This involves placing a piece of foil in a functioning ultrasonic cleaner, and then inspecting it for an even hole pattern. The problem there is that cavitation is just one factor in the ultrasonic cleaning process, as noted above. The foil test doesn’t account for the amount of detergent, the length of cleaning time, or the loading basket capacity.

Foil Test for dental instruments

 

The Solution: Cleaning Monitors

If you can’t always see leftover debris and the foil test only indicates one of the cleaning parameters, how do you monitor your cleaning process to ensure that it is effective? For a number of years, hospitals have been opting for monitors that use artificial test soils which simulate the presence of blood and tissue, to routinely check cleaning equipment. These tests provide consistent, reliable input on the cleaning process and are significantly superior to visually inspecting instruments.

Ultrasonic Cleaning Monitor In-UseHu-Friedy’s new Cleaning Monitors are an example of one of these types of products. These Cleaning Monitors are designed for monitoring the efficiency of the cleaning process when using washer-disinfectors or ultrasonic cleaners. The system consists of equipment-specific monitor strips and a reusable holder. The monitor strips contain a test soil that mimics the presence of blood and tissue that may be found on an instrument surface after its use. Full removal of the test soil from the strip during a cleaning cycle indicates an effective cleaning process. The test soil is a non-toxic, synthetic soil, so nothing hazardous is added to your cleaning solution. The stainless steel holder keeps the cleaning monitor in place in order to provide an accurate result and in the case of the washer-disinfector monitor, it mimics a hinged instrument and measures the water impingement and removal of soil.

 

Shop the Product

Hu-Friedy Cleaning MonitorsHu-Friedy Wash-Checks® Cleaning Monitors – Shop

Knowing the number of factors at play during the cleaning process, Hu-Friedy has put together a troubleshooting guide (pictured below) to help you understand what might need to change about your process to achieve a better result.

hu-friedy instrument cleaning troubleshooting guideCLICK HERE to be directed to the full-size PDF

Clean instruments lead to sterile instruments, and knowing whether or not your instruments are clean is an important element of quality assurance. Adding a product like Hu-Friedy’s Cleaning Monitors to your daily or weekly protocols gives invaluable insight into the effectiveness of your cleaning process as well as peace of mind that you are keeping yourself and your patients safe!

 

Additional Resources

  • CLICK HERE to be directed to the latest CDC communication on infection prevention in dental settings
  • CLICK HERE for a direct link Direct link to a detailed PDF of CDC Guidelines for Infection Control in Dental Health-Care Settings

 

Content provided by Hu-Friedy

OffTheCusp Guest Author

About Post Author

OffTheCusp Guest Author

http://www.Pattersondental.com
Total
0
Shares
Share 0
Tweet 0
Pin it 0
Share 0
Tagged clean, cleaning monitor, cleaning monitors, disinfect, Hu-Friedy, Infection Control, sterilization, sterilization equipment, ultrasonic

Post navigation

Previous

Previous post:

6 Tips for Protecting Your Team During Flu Season

Next

Next post:

1 Brush, 5 Modes: That’s Genius! [Giveaway]

One thought on “HOW to Know Your Instruments are Clean, and WHY it Matters!”

  1. Haynes Darlington says:
    October 5, 2016 at 11:37 am

    If inspected and there is no weekly records of an independent Biological Spore test, you are likely to be disciplined at best or face legal proceedings. Color change of strips is not an acceptable alternative.
    Dentistry whisperer (M. Pharm. D)

Comments are closed.

Subscribe

* indicates required

Recent posts

  • CLEARFIL™ Universal Bond Quick 2: Revolutionizing Dental Adhesion with Efficiency and Strength​
  • Hometown Dental and Patterson: Partners in Progress
  • Prevent & Mitigate: Helping Patients Optimize Their Oral Health
  • Tips and Tricks for Prophy Performance and Practice Growth
  • 6 Things Every Office Manager Needs to Do Right Now to Achieve Work-Life Balance

Search Off the Cusp

Close
Menu
  • Home
  • Categories
    • Business of Dentistry
      • Dental Practice Marketing
      • Practice Finance
      • Practice Growth
    • Dental Industry News
      • Industry Events
    • Dental Practice Management
      • Human Resources
    • Dental Practice Safety
      • Infection Control
    • Future of Dentistry
      • Dental Equipment
      • Dental Technology
      • CAD/CAM
  • About
    • Off The Cusp Privacy Policy
    • Off The Cusp Terms of Use
  • pattersondental.com

Related Post

CLEARFIL™ Universal Bond Quick 2: Revolutionizing Dental Adhesion with Efficiency and Strength​

May 19, 2025May 19, 2025

Tips and Tricks for Prophy Performance and Practice Growth

March 24, 2025March 24, 2025

The Injection Molding Technique: Transforming Chairside Dentistry for Greater Efficiency and Accessibility

March 10, 2025March 10, 2025

Introducing VeneerNow! Making Composite Veneer Dentistry Easier and More Efficient

March 6, 2025March 6, 2025

Why Dentists Are Choosing Chloroprene Gloves: The Perfect Balance of Comfort and Protection

September 10, 2024October 8, 2024

The Not So Small Task of Proper Glove Selection

November 16, 2023November 16, 2023
Copyright Patterson Dental. All rights reserved.
 

Loading Comments...
 

You must be logged in to post a comment.